Ultra-Low Frequency Dielectric Loss Tester
Ultra-Low Frequency Dielectric Loss Tester is capable of testing medium-voltage cables in accordance with the relevant standards of the European Committee for Electrotechnical Standardization (CENELEC) harmonization documents HD 620 S1:1996 and HD 621 S1:1996.
A 0.1Hz sine wave voltage of up to 24kV RMS. With this type of cable testing, faults in the insulation, especially water tree damage, can be reliably detected in both polyethylene (PE)/cross-linked polyethylene (XLPE) cables as well as paper-insulated cables, causing flashover. The testing procedure will not damage fault-free insulation. Cables can also be tested for dielectric breakdown strength using both positive and negative DC voltages, as well as trapezoidal AC voltage (rectangular wave voltage). The slew rate of the rectangular wave voltage depends on the cable capacitance and is automatically adjusted. Additional leakage current measurement in DC mode allows for evaluating the relative quality of the cable insulation. The sine wave shape of the system’s test voltage can also be used to directly measure the cable’s dielectric loss factor, thereby determining the degree of deterioration in the cable’s loss factor. For a detailed description of this application, please refer to the relevant manuals.
The Ultra-Low Frequency Dielectric Loss Tester combines the following features and functions:
- Full AC voltage testing up to 24/31.8 kV RMS (sine wave voltage)
- Integrated ultra-low-frequency withstand voltage and dielectric loss factor testing
- Additional output voltage waveforms of DC and rectangular waves
- Sheath testing and pinpointing up to 10 kV
- Leakage current measurement
- Manual and automatic frequency adjustment
- Voltage breakdown detection with automatic disconnection of the high-voltage connection
- Logging to internal memory, exportable to a computer via USB stick for generating test reports
- Firmware updates via USB
|
Output Voltage |
||
|
Model |
BVLF-34kV |
BVLF-45kV |
|
Output Voltage (Sine Wave) |
max.24kVRMS (34kVPEAK) |
max.31.8kVRMS (45kVPEAK) |
|
DC Voltage |
±1–34kV |
±1–45kV |
|
Resolution |
0.001kV |
0.001kV |
|
Accuracy |
1% |
1% |
|
|
Output Current |
|
|
Measurement Range |
0–14mA |
0–14mA |
|
Resolution |
1µA |
1µA |
|
Accuracy |
1% |
1% |
|
Maximum Capacitance Load |
0.1Hz@0.5µF/24kVrms/34kVpeak 0.05Hz@1.0µF/24kVrms/34kVpeak 0.01Hz@8.0µF/18kVrms/25kVpeak |
0.1Hz@0.5µF/31.8kVrms/45kVpeak 0.05Hz@1.0µF/31.8kVrms/45kVpeak 0.01Hz@5.0µF/22kVrms/31kVpeak |
|
Dielectric Loss Factor Measurement (BVLF TD) |
|||||
|
VLF-Sine |
1-24kV rms |
1-31.8kV rms |
|||
|
Load Range |
1nF-8uF |
1nF-5uF |
|||
|
Resolution |
1×10-5 |
1×10 -5 |
|||
|
Accuracy |
1×10-4 |
1×10-4 |
|||
|
Measurement Range |
1×10 -4-9999.9 x10-4 |
1×10 -4-9999.9 x10-4 |
|||
|
tan-δ Measurement Frequency |
0.1Hz |
0.1Hz |
|||
|
General Information |
|||||
|
Power Consumption |
max.300VA |
max.400VA |
|||
|
Reverse Voltage Protection |
13kV |
15kV |
|||
|
Data Interface |
USB2.0 |
||||
|
Dimensions (Width x Height xDepth) |
Peli Case 1430, 430 mm x 240 mm x 340 mm |
||||
|
Weight |
22kg |
||||
|
Ambient Temperature (Operating) |
-10 to +50°C |
||||
|
Storage Temperature |
-20 to +60°C |
||||
|
Safety and Electromagnetic Compatibility (EMC) |
Complies with CE standards, Low Voltage Directive (2014/35/EC), Electromagnetic Compatibility Directive (2014/30/EC), Environmental Impact EN60068-2 and subsequent versions |
||||
|
The user interface Provides multiple languages |
English, Chinese (Simplified), Russian, Spanish, etc. |
||||

LET’S FIND YOUR SOLUTION
Let’s find your power solution.
Tell us your application, power rating and input/output requirements. Our team will help you choose a suitable product category and configuration.